MIL-PRF-49471/8A(CR)
Abuse test, predischarge: Designated samples shall be discharged at 2.0 amperes
for 1.6 hours.
Abuse test, pulse discharge: Batteries shall be discharged at 2.5 amperes for 1
minute followed by 1.8 amperes for 4 minutes, cycled continuously to cut-off
voltage.
Closed-circuit voltage test (battery and cell string): Load resistance of 3 ohms shall be used.
Voltage shall be above 6.00 volts within 10 seconds.
Cell closed circuit voltage: Load resistance of 1 ohm shall be used. Voltage shall be above 2.0
volts within 5 seconds.