MIL-PRF-49471/11A(CR)
NOTES:
1. All dimensions are in inches.
2. Tolerances, unless otherwise specified, are +0.004 for decimals.
3. Electrical terminal contacts are 0.01 inches thick Minimum. This shall be certified in the First
Article Test Report.
REQUIREMENTS:
Dimensions and configuration: See Figure 1.
Maximum voltage: 6.60 volts.
Cut-off voltage for capacity: 4.00 volts.
Weight (maximum): 0.72 pound (327 grams).
Battery short circuit test: Applicable.
Charge protection: Applicable.
High temperature protection: Applicable.
Complete discharge device: Applicable.
State of Charge Indicator: Not applicable.
Capacity tests: When the battery is tested in accordance with the method of examination and
tests of this specification, the minimum capacity requirements shall be as specified below:
Capacity Test
Minimum Capacity Requirements
in Hours to 4.00 volts
I
3.2
L
1.7
H
5.6
HT
5.4
LT
1.5
IT
2.8
LR1
48.0
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business