MIL-B-49030/5A
Dimensions and weight.
Battery voltage.
Capacity, I, LT, and HT.
Conformance inspection.
Visual and mechanical (external)
Dimensions and weight.
Battery voltage.
Insulation-resistance test.
Vibration test.
Mechanical-shock test.
Capacity: LT, HT, T, and D.
Methods of examination and test:
Capacity tests: See requirements for capacity specified herein.
Minimum service
Test
Storage period
Temperature
required (hours)
I (Initial 70 °F)
48 hours minimum
70 °F
30
LT (0 °F)
16 hours minimum,
0 °F
4
HT (160 °F)
7 days plus
160 °F
48 hours minimum
70 °F
20
T
13 weeks plus
113 °F
48 hours minimum
70 °F
22
D
52 weeks
70 °F
24
Discharge: The battery shall be discharged through 4,500 ohms continuously to an end voltage of 40.5 volts.
Closed circuit voltage: Use TS-183( )/U per special marking or, with minimum permissible voltage as
specified for TS-183 ( )/U, use a load resistant value of 1,980 ohms.
3