MIL-B-49030/2A
First article inspection:
Vibration test.
Mechanical-shock test.
Insulation resistance test.
Visual and mechanical (external and internal).
Dimensions and weight.
Battery voltage.
Capacity, I, LT, and HT.
Conformance inspection.
Visual and mechanical (external)
Dimensions and weight.
Battery voltage.
Insulation-resistance test.
Vibration test.
Mechanical-shock test.
Capacity: LT, HT, T, and D.
Methods of examination and test:
Capacity tests: See requirements for capacity specified herein.
Minimum service
Test
Storage period
Temperature
required (hours)
I (Initial 70 °F)
48 hours minimum
70 °F
34
LT (0 °F)
16 hours minimum,
0 °F
7
HT (160 °F)
7 days plus
160 °F
48 hours minimum
70 °F
28
T
13 weeks plus
113 °F
48 hours minimum
70 °F
30
D
52 weeks
70 °F
32
Discharge: The battery shall be discharged through 600 ohms continuously to an end voltage of 27.0 volts.
3